Configuration Guide - RMS Detectors and Ratemeters for Area Monitoring


View full version of this Brochure (PDF)

Description

Large Area Monitoring System, Nuclear Power PlantThe modular design of CANBERRA’s SMART detectors, ratemeters, and auxiliary alarm systems offers the benefits of achieving multiple setup configurations to serve all area radiation monitoring needs. Optional RADACS (Radiological Assessment Display and Control System) software enables remote radiation data management from your PC. Provided appropriate security access and network connection are available, the radiation monitoring data can be viewed real-time by third parties.

Size of the area monitoring system could vary from relatively small – composed of only a few detectors – to very large – made up of hundreds of detectors.

Large systems are typical in nuclear power plant monitoring, HLW/LLW repositories, fuel fabrication or reprocessing plants, research reactors, and university or medical labs.

More recent, radiation area monitoring systems have been successfully extended into homeland security applications where RADACS enables for fast and accurate security decision making.

Our safety qualified components are designed and built to pass seismic requirements. Testing for seismic qualification is specially performed and is based on customer provided frequency spectrum data.

This configuration guide addresses two basic radiation monitoring setups – local and remote configurations for use in safety and nonsafety applications. In the local configuration the ratemeter(s) is placed in a control room where all monitoring takes place. In a remote configuration, the additional ratemeter(s) is placed at some distance from the local one, enabling remote monitoring.

The following standard components are being used:

  • SMART detectors: Ion Chamber Detectors – IP and ICP Series; Geiger Müeller Detectors – GP Series and GSP100 detector; Neutron Probes – NP Series.
  • Ratemeters: Rack mount ADM606, Portable ADM606M and Wall mount ADM616.
  • Auxiliary Alarm – AX302.
  • RADACS – Small, Medium or Large packages, based on the number of sensors.

The specific requirements of each application will dictate the type of the SMART detectors, ratemeters, additional alarms or RADACS model needed.

There are two options in terms of raw cables – plenum or 1E rated. The plenum rated cable meets the requirements defined under UL910 code which regulates fire resistance and low-smoke characteristics. The 1E nuclear grade cable meets the requirements of IEEE 383 for nuclear power plants.

For complete specifications, please see the individual component data sheets.

The tables below identify terminated and raw cables, detectors and ratemeters with their respective connectors needed for configuring an area monitoring system. The auxiliary equipment refers to a preamplifier (PA100M) or current to frequency converter (CF300), required between some detectors and ratemeters.

NON-SAFETY Applications
NON-SAFETY, NON-NUCLEAR APPS
ADM606 and ADM616 ADM606M
Detector Model Connector Auxiliary
Equipment
Raw
Cable
Terminated
Cable
Raw
Cable
Terminated
Cable
GP Series GP100
GP100SI
12-pin MS N/A C1733-X C1745T-X C1731-X C1730T-X
GP100C
GP100CS
12-pin MS N/A C1733-X C1745T-X N/A N/A
GP110
GP110SI
7-pin Hiroshi N/A C1731-X C1746T-X C1731-X C1743T-X
GP100M
GP100MS
12-pin MS C1745T-X
to PA100M
C1733-X C1745T-X C1731-X C1730T-X
GSP100 GSP100 7-pin Hiroshi N/A C1731-X C1746T-X C1731T-X C1743T-X
IP Series IP100
IP100SI
12-pin MS N/A C1733-X C1745T-X C1733-X C1730T-X
IP100C
IP100CS
12-pin MS N/A C1733-X C1745T-X N/A N/A
NP Series NP100H 12-pin MS N/A C1733-X C1745T-X C1731-X C1730-X
NP100B
AX302 AX302 N/A C1731-X
Remote Ratemeter ADM606 Three 12-pin
MS
N/A C1732-X C1750T-X
ADM606M Three 7-pin
Hiroshi and
Three DB15
ADM616 Three 12-pin
MS
PC RADACS PC, COM1 DB 9 N/A C1732-X N/A C1732-X N/A
Power Ratemeter provides power
to detector
N/A C1735-X with Ring Lugs Power cord

SAFETY Applications

SAFETY, NUCLEAR APPS

ADM606 and ADM616

Detector

Model

Connector

Auxiliary
Equipment

Raw
Cable

Terminated
Cable

GP Series

GP100
GP100SI

12-pin MS

N/A

C1734-X

C1740T-X

GP100C
GP100CS

12-pin MS

N/A

C1734-X

C1740T-X

GP100M
GP100MS

12-pin MS

C1744T-X to PA100M

C1734-X

C1740T-X

IP Series

IP100
IP100SI

12-pin MS

N/A

C1734-X

C1740T-X

IP100C
IP100CS

12-pin MS

N/A

C1734-X

C1740T-X

ICP100H
ICP100L
ICP100LS

HN

Two cables C1747T-X to CF300 (one for signal and one for HV)

C1734-X

C1752T-X

NP Series

NP100H

12-pin MS

N/A

C1734-X

C1740T-X

NP100B

AX302

AX302

N/A

C1737-X

Remote
Ratemeter

ADM606

Three 12-pin MS

N/A

C1735-X

C1749T-X

ADM616

PC RADACS

PC COM1

DB 9

N/A

C1735-X

Power

Ratemeter provides power to detector

N/A

C1735-X with Ring Lugs

Maximum Distances Between Detectors to Ratemeters
  • GP Series (except GP100M) to Ratemeter: 30 m (100 ft).
  • GP100M to PA100M: 60 m (200 ft); PA100M to Ratemeter: 30 m (100 ft).
  • GSP100 to Ratemeter: 90 m (300 ft).
  • IP Series (except ICP) to Ratemeter: 90 m (300 ft).
  • ICP to CF300: 120 m (400 ft); CF300 to Ratemeter: 90 m (300 ft).
  • NP Series to Ratemeter: 30 m (100 ft).

Auxiliary local alarm units can be installed throughout the facility to alert personnel of alarm conditions at a secondary location, separate from the primary measurement and display ratemeter. The AX302 model comes with red light, horn and analog meter. It can be placed up to 90 m (300 ft) away from the ratemeter.

Model
Description
1E grade
C1730T-X
C1731-X
C1732-X
C1733-X
C1734-X
C1735-X
C1737-X
C1738-X
C1740T-X
C1741T-X
C1742T-X
C1743T-X
C1744T-X
C1745T-X
C1746T-X
C1747T-X
C1749T-X
C1750T-X
C1751T-X
C1752T-X
Terminated, 9-conductor, 12-pin MS to DB15
9-conductor
3-conductor
12-conductor
14-conductor
4-conductor
8-conductor
Triax cable
Terminated, 14-conductor, 12-pin MS to 12-pin MS
Terminated, 2-conductor, 3-pin MS to ring lugs
Terminated, 8-conductor, 12-pin MS to 19-pin MS
Terminated, 9-conductor, 7-pin Hiroshi to DB15
Terminated, 8-conductor, 12-pin MS to 12-pin MS
Terminated, 12-conductor, 12-pin MS to 12-pin MS
Terminated, 9-conductor cable, 7-pin Hiroshi to 12-pin MS
Terminated, triax cable, HN to HN
Terminated, 4-conductor, communication cable, ring lugs on both ends
Terminated, 3-conductor, communication cable, ring lugs on both ends
Terminated, 12-conductor, 12-pin MS to 12-pin MS, PA300E to ratemeter
Terminated, 14-conductor, 12-pin MS to 12-pin MS, CF300 to ratemeter
N
N
N
N
Y
Y
Y
Y
Y
Y
Y
N
Y
N
N
Y
Y
N
N
Y