Configuration Guide - RMS Detectors and Ratemeters for Area Monitoring
|
Description
The modular design
of CANBERRA’s SMART
detectors, ratemeters,
and auxiliary alarm
systems offers the
benefits of achieving
multiple setup configurations
to serve all area
radiation monitoring
needs. Optional
RADACS (Radiological
Assessment Display and
Control System)
software enables remote
radiation data management
from your PC.
Provided appropriate
security access and
network connection are
available, the radiation
monitoring data can be
viewed real-time by
third parties.
Size of the area monitoring system could vary from relatively small – composed of only a few detectors – to very large – made up of hundreds of detectors.
Large systems are typical in nuclear power plant monitoring, HLW/LLW repositories, fuel fabrication or reprocessing plants, research reactors, and university or medical labs.
More recent, radiation area monitoring systems have been successfully extended into homeland security applications where RADACS enables for fast and accurate security decision making.
Our safety qualified components are designed and built to pass seismic requirements. Testing for seismic qualification is specially performed and is based on customer provided frequency spectrum data.
This configuration guide addresses two basic radiation monitoring setups – local and remote configurations for use in safety and nonsafety applications. In the local configuration the ratemeter(s) is placed in a control room where all monitoring takes place. In a remote configuration, the additional ratemeter(s) is placed at some distance from the local one, enabling remote monitoring.
The following standard components are being used:
- SMART detectors: Ion Chamber Detectors – IP and ICP Series; Geiger Müeller Detectors – GP Series and GSP100 detector; Neutron Probes – NP Series.
- Ratemeters: Rack mount ADM606, Portable ADM606M and Wall mount ADM616.
- Auxiliary Alarm – AX302.
- RADACS – Small, Medium or Large packages, based on the number of sensors.
The specific requirements of each application will dictate the type of the SMART detectors, ratemeters, additional alarms or RADACS model needed.
There are two options in terms of raw cables – plenum or 1E rated. The plenum rated cable meets the requirements defined under UL910 code which regulates fire resistance and low-smoke characteristics. The 1E nuclear grade cable meets the requirements of IEEE 383 for nuclear power plants.
For complete specifications, please see the individual component data sheets.
The tables below identify terminated and raw cables, detectors and ratemeters with their respective connectors needed for configuring an area monitoring system. The auxiliary equipment refers to a preamplifier (PA100M) or current to frequency converter (CF300), required between some detectors and ratemeters.
NON-SAFETY Applications
| NON-SAFETY, NON-NUCLEAR APPS | |||||||
| ADM606 and ADM616 | ADM606M | ||||||
| Detector | Model | Connector | Auxiliary Equipment |
Raw Cable |
Terminated Cable |
Raw Cable |
Terminated Cable |
| GP Series | GP100 GP100SI |
12-pin MS | N/A | C1733-X | C1745T-X | C1731-X | C1730T-X |
| GP100C GP100CS |
12-pin MS | N/A | C1733-X | C1745T-X | N/A | N/A | |
| GP110 GP110SI |
7-pin Hiroshi | N/A | C1731-X | C1746T-X | C1731-X | C1743T-X | |
| GP100M GP100MS |
12-pin MS | C1745T-X to PA100M |
C1733-X | C1745T-X | C1731-X | C1730T-X | |
| GSP100 | GSP100 | 7-pin Hiroshi | N/A | C1731-X | C1746T-X | C1731T-X | C1743T-X |
| IP Series | IP100 IP100SI |
12-pin MS | N/A | C1733-X | C1745T-X | C1733-X | C1730T-X |
| IP100C IP100CS |
12-pin MS | N/A | C1733-X | C1745T-X | N/A | N/A | |
| NP Series | NP100H | 12-pin MS | N/A | C1733-X | C1745T-X | C1731-X | C1730-X |
| NP100B | |||||||
| AX302 | AX302 | N/A | C1731-X | ||||
| Remote Ratemeter | ADM606 | Three 12-pin MS |
N/A | C1732-X | C1750T-X | ||
| ADM606M | Three 7-pin Hiroshi and Three DB15 |
||||||
| ADM616 | Three 12-pin MS |
||||||
| PC RADACS | PC, COM1 | DB 9 | N/A | C1732-X | N/A | C1732-X | N/A |
| Power | Ratemeter provides power to detector |
N/A | C1735-X with Ring Lugs | Power cord | |||
SAFETY Applications
|
SAFETY, NUCLEAR APPS |
|||||
|
ADM606 and ADM616 |
|||||
|
Detector
|
Model
|
Connector
|
Auxiliary |
Raw |
Terminated |
|
GP Series
|
GP100 |
12-pin MS |
N/A |
C1734-X |
C1740T-X |
|
GP100C |
12-pin MS |
N/A |
C1734-X |
C1740T-X |
|
|
GP100M |
12-pin MS |
C1744T-X to PA100M |
C1734-X |
C1740T-X |
|
|
IP Series
|
IP100 |
12-pin MS |
N/A |
C1734-X |
C1740T-X |
|
IP100C |
12-pin MS |
N/A |
C1734-X |
C1740T-X |
|
|
ICP100H |
HN |
Two cables C1747T-X to CF300 (one for signal and one for HV) |
C1734-X |
C1752T-X |
|
|
NP Series
|
NP100H |
12-pin MS |
N/A |
C1734-X |
C1740T-X |
|
NP100B |
|||||
|
AX302 |
AX302 |
N/A |
C1737-X |
||
|
Remote |
ADM606 |
Three 12-pin MS |
N/A |
C1735-X |
C1749T-X |
|
ADM616 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PC RADACS |
PC COM1 |
DB 9 |
N/A |
C1735-X |
|
|
Power |
Ratemeter provides power to detector |
N/A |
C1735-X with Ring Lugs |
||
Maximum Distances Between Detectors to Ratemeters
- GP Series (except GP100M) to Ratemeter: 30 m (100 ft).
- GP100M to PA100M: 60 m (200 ft); PA100M to Ratemeter: 30 m (100 ft).
- GSP100 to Ratemeter: 90 m (300 ft).
- IP Series (except ICP) to Ratemeter: 90 m (300 ft).
- ICP to CF300: 120 m (400 ft); CF300 to Ratemeter: 90 m (300 ft).
- NP Series to Ratemeter: 30 m (100 ft).
Auxiliary local alarm units can be installed throughout the facility to alert personnel of alarm conditions at a secondary location, separate from the primary measurement and display ratemeter. The AX302 model comes with red light, horn and analog meter. It can be placed up to 90 m (300 ft) away from the ratemeter.
Model |
Description |
1E grade |
| C1730T-X C1731-X C1732-X C1733-X C1734-X C1735-X C1737-X C1738-X C1740T-X C1741T-X C1742T-X C1743T-X C1744T-X C1745T-X C1746T-X C1747T-X C1749T-X C1750T-X C1751T-X C1752T-X |
Terminated, 9-conductor, 12-pin MS to DB15 9-conductor 3-conductor 12-conductor 14-conductor 4-conductor 8-conductor Triax cable Terminated, 14-conductor, 12-pin MS to 12-pin MS Terminated, 2-conductor, 3-pin MS to ring lugs Terminated, 8-conductor, 12-pin MS to 19-pin MS Terminated, 9-conductor, 7-pin Hiroshi to DB15 Terminated, 8-conductor, 12-pin MS to 12-pin MS Terminated, 12-conductor, 12-pin MS to 12-pin MS Terminated, 9-conductor cable, 7-pin Hiroshi to 12-pin MS Terminated, triax cable, HN to HN Terminated, 4-conductor, communication cable, ring lugs on both ends Terminated, 3-conductor, communication cable, ring lugs on both ends Terminated, 12-conductor, 12-pin MS to 12-pin MS, PA300E to ratemeter Terminated, 14-conductor, 12-pin MS to 12-pin MS, CF300 to ratemeter |
N N N N Y Y Y Y Y Y Y N Y N N Y Y N N Y |
|
| Top of Page |
Email Us or via phone
In the United States
(800) 243-3955
Outside United States:
(203) 238-2351
Reference Material