iCAM/MF Moving Filter Head for iCAM
Features
- Automatic filter change mechanism
- Twelve months autonomous operation
- Fluoroporeâ„¢ FSLW filter roll
- Filter ΔP measurement
- Retro-fittable to existing iCAMs
- Automatically detected and configured
- For ambient sampling or remote connection via standard air inlet adaptor
Benefits
- Long term unattended operation in inaccessible or unfrequented locations
- Reduced operating costs
- Improved performance - through use of higher resolution filter
- Preset time interval
- Preset air volume
- High filter pressure drop
- Low flow
- High activity
- High radon/thoron background
Fluoropore is a trademark of Millipore Corporation.
Description
The iCAM/MF moving filter detector head provides iCAM users with an option in filter handling. In place of the fixed, card mounted filter, which must be changed manually at regular intervals, the mechanism passes a continuous belt of filter material under the detector. Hence, when a filter change is required, instead of manual intervention being necessary, the iCAM firmware commands the mechanism to step the filter on, presenting a clean piece of filter material to the detector. The length of the filter roll, combined with the ability of the iCAM compensation algorithms to adapt to filter spectrum shape changes, allows up to twelve months operation with no manual intervention in typical applications. This renders the iCAM/MF ideal for use in hazardous or inaccessible areas where frequent personnel access is undesirable, e.g., long term unattended environmental monitoring. It also allows the iCAM to operate in high dust-loading environments, where otherwise frequent manual filter changes would be required. The sampling head can draw an air sample either directly from the ambient air or remotely via a 1 in. bore hose or pipe connected via the standard iCAM air inlet adaptor.
The mechanism incorporates measurement of the pressure drop across the filter, to assist in determining when a filter change is necessary. The iCAM firmware (V200 or greater) automatically detects the presence of the moving filter mechanism, and can change the filter on any or all of the following conditions:
The trigger values for all these conditions are user-settable parameters. Apart from detecting and controlling the moving filter mechanism, the iCAM detectors, firmware and display screens etc. are unchanged. The radon/thoron compensation algorithms operate as in the standard iCAM, but there is a significant improvement in detection performance as the FSLW filter gives better resolution that the standard GFA filter:
The mechanism is compatible with all existing iCAMs and existing fixed filter heads can be replaced with a moving filter mechanism if required.
The mechanism incorporates the same air inlet nozzle as is used on the standard fixed filter iCAM, giving excellent particulate collection performance across a wide range of particle sizes. A source jig is available which allows use of existing iCAM calibration sources with the mechanism. Alternatively customized source jigs can be produced to allow use of suitable alternative calibration sources. For sampling from discharge stacks or process ducts the standard iCAM air inlet adaptor (option ICAM/A) can be used, allowing the connection of a sample pipe.
![]() ![]() |
Note to our International Customers: If you would like a quote on this product, please contact your Local Sales Office for assistance. |
||
| Models | Description | |
| iCAM/MF | Supplied with unterminated European 2 m (6.5 ft) AC power cord and wall mounting brackets. | |
| iCAM/MFUS | Supplied with 2 m (6.5 ft) US power cord and plug, and wall mounting brackets. | |