Series 5 XLB Automatic Low Background Alpha/Beta Counting System
Features
- Automatic single detector, ultra-low background counting system
- Enhanced low background capability
- Gas Stat digital gas conservation and monitoring system
- Fifty planchet sample changer with 100 sample capacity optional
- Molded low background passive shielding with interlocking design
- Reduced system footprint and integrated portable cart
- High performance 5.7 cm (2.25 in.) gas flow detector with ultra thin window 80 µg/cm2; one inch detector option
- Advanced electronic diagnostics continuously monitor operating conditions
- Universal auto-sensing power supply
- Coded positive sample carrier identification
- External or sample changer based bar code reader
- CE compliant
Description
Superior Counting Performance, Unparalleled System Features
The Series 5 XLB is the only low background alpha/beta counter to offer a completely integrated, computer controlled system for maximum flexibility. A counting solution so advanced, yet easy to operate.
The Series 5 platform is the next generation of automatic low background systems, designed to count samples the way they are prepared in a laboratory. Sensible and smart, the Series 5 provides integrated intelligence to satisfy the most demanding applications and routine analysis.
Enhanced Low Background and Productivity - Simply the Best
Due to increasing environmental regulations to reach lower detection limits, sample count times have increased reducing the overall sample throughput in the laboratory. The Series 5 incorporates new technology to reduce system background and increase sample throughput. Using an improved guard detector, the system sensitivity for high energy, cosmic background is increased, enabling the anti-coincidence circuitry to detect and reject more spurious background events.
The beta background for the Series 5 has been reduced by as much as 35% over older systems. Beta backgrounds as low as 0.5 cpm can be achieved. This means that the Series 5 family of low background counters can count twice as many samples for a given detection limit as a counter with a beta background of 1.0 cpm - impressive performance from an impressive system.
Custom Molded Shield
Using a graded shielding system, the
Series 5 counts samples with more accuracy than any other low background
counter.
The molded shield system provides 10 cm (4 in.) of custom molded lead surrounding the detector. The shield comprises interlocking modules which weigh no more than 27 kg (60 lb) each for safety and ease of assembly.
Time Proven Reliability
The sample changer of the Series 5 family is time and field proven. The highly reliable design of the automated sample changer transports and counts samples day after day providing worry free operation. When work counts and time is precious, count on a system to deliver results and reliability.
Ultra-Thin Detector Windows
The standard gas flow detector of the Series 5 family of systems incorporates a high performance pancake-style 5.7 cm (2.25 in.) detector. The entrance window of the detector is made with state-of-the-art technology and special materials to provide the highest counting efficiency and the lowest alpha background of any counter. Standard detector windows are 80 µg/cm2 with 500 µg/cm2 window as an option.
Positive Sample Identification and Bar Code - The Advantage
Today…trade's changing requirements demand sample identification that is maintained through the counting data. Data defensibility is a priority. The Series 5 incorporates a unique combination of carrier and sample identification systems to maintain chain-of-custody. Two methods of sample identification are linked to the final data report. The sample carrier is uniquely coded for routine analysis. The Series 5 can be configured with an automatic sample bar code reader. When present, the sample bar code is automatically captured by the Eclipse software and stored with the sample count data, forming the missing link in sample custody in the count room. Only CANBERRA sample carriers are washable for easy cleaning and decontamination.
Circuitry So Advanced, It Thinks for Itself
The advanced electronics package of the Series 5 family of counting systems provides the most advanced control and monitoring system available to assure accurate results. The Series 5 incorporates hardware diagnostics which continuously monitor internal and external parameters including gas pressure and flow, system voltage, power distribution, and other system critical parameters. The user is alerted on the front panel if any of these parameters falls below normal operation thresholds.
Human Factor Engineering
Often computer controlled analytical equipment requires additional laboratory space for the computer system and peripherals. The Series 5 addresses that problem with an integrated mobile cart that provides all of the support necessary for the computer, monitor, keyboard, and pointing device. The optional S5-ACCKIT includes a monitor support shelf tray, printer support tray, and a gas tank bracket. The retractable printer shelf opens to hold printer and supplies. The Series 5 is designed to be a completely integrated, self contained counting system with the industry…trade's smallest footprint.
Gas Stat Gas Conservation System
Conventional low background counters have manual gas flow control and use the equivalent of a 1A gas cylinder on the average of once per six weeks. Changing gas supplies usually means re-verification of critical system calibrations which can be an unnecessary time consuming process. Not only time, but the impact on data quality can become significant issues when frequent re-calibrations must be performed, due to a change in gas quality.
The Series 5 with Gas Stat sets a new standard in the industry for eliminating the high frequency of re-calibrations due to counting gas changes.
The Series 5 incorporates a microprocessor-controlled gas monitoring and control system that provides worry free operation. Gas Stat eliminates the need to adjust manual flow meters, and flow rates are digitally displayed in real time on screen. The normal gas flow rate is set by the operator through software control. The Series 5 hardware senses when the system is not counting samples, and automatically reduces the gas flow rate to a low quiescent flow to maintain detector gas quality. This prevents atmospheric impurities from diffusing into the detector and causing questionable results. When the user starts a count, Gas Stat automatically purges the detector and resets the flow rate to normal. Gas Stat uses a preset maximum flow rate for the detector purging; so, it is virtually impossible to cause window damage due to over pressurization.
Gas Stat effectively increases the useful life of the gas supply, thereby reducing the frequency of instrument re-verification, saving time and improving the quality of counting data.
Eclipse - Powerful and Flexible
The Series 5 has been designed to take full advantage of computer based
system integration. Series 5 XLB uses the Eclipse software to provide the optimum
combination of power and ease of use for a low background system.
Eclipse is a true 32-bit multi-tasking Windows application that uses an industry standard database for storage of count data. The Microsoft Access database also allows for easy interfacing to network systems, since it is ODBC compliant and supports SQL operations. Custom reports can be easily developed for your application or presentation using a powerful sophisticated reporting application.
Final activity results can be viewed on-screen for each sample as it is counted. An intuitive, symbolic icon tool bar provides access to functions at the push of a button.
![]()
No other counter can match the advanced automation capabilities and features of the Series 5 XLB and Eclipse Software.
QUESTIONS? 
In the United States
(800) 243-3955
Outside United States:
(203) 238-2351