REGIONAL ACCESS

EXTRANET ACCESS

ISOCS Shield Systems
For more detailed information click here  > >
Product Spec Sheet PDF Format

Features

  • Portable Germanium detector shield system for in situ assays.
  • Includes 25 mm and 50 mm thick lead shields.
  • Reduces interfering 1000 keV radiation a factor of 7.5 (25 mm) and 60 (50 mm).
  • Modular design for easy handling.
  • Stainless steel construction or epoxy paint for ease of cleaning.
  • Includes 30° and 90° collimators (each thickness) plus solid end caps for background measurements.
  • Includes a rear shield plug (requires RDC option on detector).
  • Wheeled mounting stand for ease in moving the shield from one sample to the next.
  • Upper and lower detector mounting positions, with 180° detector rotation at either location.
  • Easy to assemble and to change detector positions.
  • Built-in laser aiming device.
  • Components from 25 mm and 50 mm shields may be combined to build a sample counting chamber.
ISOCS Shield Systems : The ISOCS Shield Systems and all of their available components installed on an RDC Ge Detector with a Big MAC Dewar.

Description

Figure 2: Using the ISOCS Shield System to assay a wall. This ISOCS (In Situ Object Counting System) Shield (Figure 1) has been designed as the optimum in convenience and function-ality for in situ gamma spectroscopy with a Germanium detector. The system is supplied with both 25 mm and 50 mm lead shielding which gives you the ability to utilize the sensitivity and low background capabilities of a laboratory grade Germanium spectrometer directly on site, regardless of where that site is located.

Unshielded, the detector has a nearly 360° field of view, and can be used for 4p counting of the walls/floors/contents of an entire room. The field of view can be reduced (Figure 2) by adding the shield and collimators to provide fields of view of 30°, 90°, and nearly 180° by simply sliding the appropriate shield components on the mounting rails. In addition, a completely shielded sample chamber can be assembled by combining the components from the two systems.

Its standard wheeled mounting stand makes it easy to move the shield at the assay site.

The mounting stand features both an upper (for 1-meter detector/ground counting) and lower (normal) detector mounting location, plus allows 180° detector rotation at either location, for maximum positioning flexibility. The detector holder even includes a laser pointer to aid in aiming the detector at remote objects.

Whatever the sample and wherever it's located, the ISOCS Shield System has the versatility and flexibility to count it.


Note to our International Customers: If you would like a quote on this product, please contact your Local Sales Office for assistance.

Models Description
ISOXSHLD ISOCS Shield Set

QUESTIONS?

In the United States
(800) 243-3955

Outside United States:
(203) 238-2351