JCC-13/14: Sample Inventory Coincidence Counters
|
Features
- Authorized for routine inspection use as the INVS, Inventory Sample Coincidence Counter.
- Designed for passive neutron assay of plutonium.
- High counting efficiency - 42%.
- Variable sample cavity size.
- Fast Amptek electronics.
- 18 3He detectors.
- Transportable.
- Optional transport container.
Description
The JCC-13 and JCC-14 are based on a design developed
at Los Alamos National Laboratories (LANL) in the United
States under the United States Department of Energy
development programs. They have also been authorized for routine inspection
use of nuclear material
at facilities placed under international safeguards.
The JCC-14 is designed to assay plutonium inventory samples inside a glovebox. It is an upgraded version of the JCC-121, and fits around the drywell of the glovebox2. Samples are loaded into an aluminum carrier inside the glovebox and then lowered into the JCC-14 for counting. The JCC-13 which is a modification of the Los Alamos National Laboratory design, differs only in the sample diameter and the method of sample loading. The JCC-13 is slightly larger in diameter than the JCC-14, and uses top loading to minimize torn sample bags. The JCC-13 is a transportable counter, designed for verification inspections at multiple sites.
The JCC-13 and JCC-14 provide a flatter axial response and higher efficiency than the JCC-12. The cylindrical-shaped sample holder accommodates various samples including liquids, powders and pellets. The sample cavity can be enlarged by removing the polyethylene sleeve around the aluminum sample carrier. However, enlarging the sample cavity decreases efficiency and makes the measurement more sensitive to hydrogen in the sample. The counter is intended to operate in the 0.1 to 500 g Pu mass range. A JSR-12 Neutron Coincidence Analyzer, a computer and analysis software are required for coincidence counting but are not included with the JCC-13 or JCC-14.
A cadmium sleeve lines the central region of the sample cavity to flatten the response profile along the length of the 3He tubes. The graphite end plugs act as reflectors. Surrounding the sample cavity is a ring of high-density polyethylene with 18 3He proportional detectors embedded in the polyethylene. The tubes are arranged in two concentric rings to maximize detector efficiency. The tubes are divided into three groups of six. Each group is wired together and connected to one JAB-01 Amplifier/Discriminator circuit board. The three JAB-01s are mounted inside the high voltage junction box with LED indicator lights mounted externally on the junction box to indicate proper operation of each JAB-01 channel. Electrical connections between the JCC-13 or JCC-14 and the JSR-12 Neutron Coincidence Analyzer include +5 V, HV, and a single "ORed" output signal.
The detector is portable and fits into an optional carrying case for transport.
|