- High-purity Germanium Detectors
- Cryostats, coolers & options
- Detectors Shields
- Silicon Lithium Si(Li) Detectors
- Special Ge and Silicon Lithium Si(Li) Detectors
- Scintillation Detectors & options
- Passivated Implanted Planar Silicon (PIPS) Detector
- Geiger Muller (GM) Detectors
- X-Ray Detectors for Synchrotron (EXAFS) Applications
Geiger Mueller (GM) Detectors
Description
CANBERRA Geiger Mueller Detectors have been carefully researched and developed to provide a rugged, reliable, long-lasting means of monitoring nuclear radiation levels. These detectors offer guaranteed advantages, including manufacturing consistency, product reliability and competitive pricing. Many of our tube types, including those approved for the military Quality Product List (QPL), are manufactured and tested to withstand rigorous shock and vibration per military standards.
Products in category
GM Pancake Detectors (Halogen Quenched)
Description
Pancake detectors are widely used in nuclear probes and instruments for detecting and measuring alpha, beta or gamma surface contamination of clothes, small objects, benches, floors, roads, etc. Such halogen-quenched Geiger Mueller detectors are cost-effective, have an unmatched quality/cost ratio, are easy to use and are very reliable. Their ultra-thin mica window allows for an efficient detection of alpha, low energy beta and gamma radiation.
Adherence to stringent design parameters, manufacturing procedures and quality assurance provisions of CANBERRA products has successfully fulfilled commercial and military exacting standards. Our military approved detectors used by military customers worldwide, are able to withstand rigorous shock and vibration testing.
Our 2000-series of GM detectors provides a direct-replacement to most widely used competitive detectors. These can be incorporated into various radiation monitors and dosimeters. Our GM pancake detectors range in diameter from 33.5 mm (1.32 in.) to 53.6 mm (2.11 in.) and are also offered in Low Hysteresis and High Altitude models. These are used in CANBERRA's own line of products as well as products from various companies. Please contact us should you wish to discuss specific requirements or references.
Features
- 1.8 to 2.2 mg/cm2 Ultra Thin Mica Window
- 28 or 45 mm effective diameter
- High alpha, beta and gamma efficiency
- Cost effective, easy to use and very reliable with unmatched quality/cost ratio

| Characteristics | Detector Type (for α, β, γ applications) | |||||||
| T2000/8767** T2000/900 LH T2000/900 HA |
T2000/500 T2000/500 LH T2000/500 HA |
T2006/900 T2006/900 LH |
T2006/500 T2006/500 LH |
T2011/900 | T2011/500 | |||
| Applications | SBM-2D, SBS | BP-100 | - | BP-77 | MCB2, SABG-15 | - | ||
| Sensitivity* 137Cs cpm at 1 mR/h* |
3500 | 3500 | 3500 | 3500 | 1500 | 1500 | ||
| Window Area Density (mg/cm2) | 1.8- 2.0 | 1.8- 2.0 | 1.8- 2.2 | 1.8- 2.2 | 1.8-2.0 | 1.8-2.0 | ||
| Window Effective Diameter (mm, in.) | 44.5, 1.75 | 44.5, 1.75 | 44.5, 1.75 | 44.5, 1.75 | 28.4, 1.12 | 28.4, 1.12 | ||
| Recommended Operating Voltage (HV+) | 900 | 500 | 900 | 500 | 900 | 500 | ||
| Plateau Length Volts min. | 850-1000 | 450-600 | 850-1000 | 450-600 | 850-1000 | 450-600 | ||
| Plateau Slope (%100 V max.) | 10 | 10 | 10 | 10 | 5 | 5 | ||
| Dead Time (µs max.) | 50 | 50 | 50 | 50 | 40 | 40 | ||
| Background (cpm) Shielding 2" Pb + 1/8" Al |
30 max. | 30 max. | 30 max. | 30 max. | 18 max. | 18 max. | ||
| Resistor Ra (MΩ) | 3.3 | 3.3 | 3.3 | 3.3 | 3.3 | 3.3 | ||
| Resistor R1 (MΩ) | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | ||
| Operating Temp. (°C) | –20 to +55 | –20 to +55 | –20 to +55 | –20 to +55 | –20 to +55 | –20 to +55 | ||
| Cathode Material | Cr/Fe | Cr/Fe | Cr/Fe | Cr/Fe | Cr/Fe | Cr/Fe | ||
| Max. Overall Length including Pins (mm, in.) | ![]() LH = Low Hysteresis Model |
![]() |
![]() OPTIONS: |
|||||
| Max. Overall Diameter (mm, in.) | ||||||||
| Window Recess (mm, in.) | 1.6, 0.062 | 1.6, 0.062 | 1.6, 0.062 | 1.6, 0.062 | 1.3, 0.05 | 1.3, 0.05 | ||
| * At recommended operating voltage
** The only Mil. Spec. Pancake is the "jan 8767" |
||||||||
GM End Window Detectors
Description
Our GM End Window detectors provides direct-replacement to most widely used competitive detectors. These can be incorporated into various radiation monitors and dosimeters. Our GM End Window detectors are offered in two diameters: either 19.8 mm (0.78 in.) or 28.4 mm (1.12 in.). These are used in CANBERRA's own line of products as well as products from various companies. Please contact us should you wish to discuss specific requirements or references.
Features
- 1.8 to 2.2 mg/cm2 Ultra Thin Mica Window
- 19.8 or 28.4 mm effective diameter
- High alpha, beta and gamma efficiency
- Cost effective, easy to use and very reliable with unmatched quality/cost ratio

| Mica End Window (for α, β, γ Applications) | ||||
![]() |
![]() |
![]() |
![]() |
|
| Mil. Version 2121 M Window 2.8–3.4 mg/cm2 | Probe contains 2131 tube. Available with BNC. | |||
| Characteristics | T2121 | TP2121S | TP2131 | TP2131/4P |
| Application | α, β, γ | α, β, γ | α, β, γ | α, β, γ |
| Sensitivity*
137Cs cpm at 1 mR/h* |
1700 |
1700 |
2400 |
2400 |
| Window Area Density (mg/cm2) | 1.8 – 2.2 | 1.8 – 2.2 | 1.8 – 2.0 | 1.8 – 2.0 |
| Window Effective Diameter (mm, in.) | 19.8, 0.78 | 19.8, 0.78 | 28.4, 1.12 | 28.4, 1.12 |
| Recommended Operating Voltage (HV+) | 500 | 500 | 900 | 900 |
| Plateau Length Volts min. | 450 – 700 | 850 – 1000 | 850 – 1000 | 850 – 1000 |
| Plateau Slope (%100 V max.) | 5 | 5 | 10 | 10 |
| Dead Time (µs max.) | 100 | 100 | 150 | 150 |
| Background (cpm) Shielding 2" Pb + 1/8" Al |
30 max. | 30 max. | 40 max. | 40 max. |
| Resistor Ra (MΩ) | 3.3 | 1.0 | 1.0 | 1.0 |
| Resistor R1 (MΩ) | 1.0 | 1.0 | 1.0 | 1.0 |
| Operating Temp. (°C) | –40 to +75 | –40 to +75 | –40 to +75 | –40 to +75 |
| Cathode Material | Cr/Fe | Cr/Fe | Cr/Fe | Cr/Fe |
| Max. Overall Length including Pins (mm, in.) | 51.0, 2.0 | 94, 3.7 | 124, 4.85 | 115, 54 |
| Max. Overall Diameter (mm, in.) | 25.4, 1.0 | 82, 3.22 | 35 – 1.38 | 35, 1.38 |
| Window Recess (mm, in.) | 1.6, 0.062 | 1.6, 0.062 | 1.6, 0.062 | 1.3, 0.05 |
| * At recommended operating voltage. | ||||
| Detector Type | Applications |
| T2121M | Military |
| TP2131 | Radiation monitors with BNC connection |
| T2131-4P | Radiation monitors with 4 pin JEDEC connection |
| Related Industry Models | ||||
| CANBERRA | Centronics | LND | Saint Gobain | |
| Mica End Window Detectors |
T2121 | ZP1410 | 7224 | N/A |
| T2131 | N/A | 723 | N210-1 | |
| TP2131 | N/A | 7232 | N210/BNC | |
| Related Industry Models | |||
| CANBERRA | LND | Saint Gobain | |
| Pancake | T200/8767 | 7311 | N1002/8767 |
| T2006/900 | 73118 | N1006 | |
| T2011/500 | 7231 | N1004 | |
GM Gamma & Gamma/Beta Sensitive Detectors
Description
Our gamma and gamma/beta detectors are designed to handle harsh environments, and have a very long operating lifetime in excess of 5 x 1010 counts. These are offered in a wide range of lengths (51 mm to 351 mm) and diameters of (15.2 mm to 19.3 mm) and can be used as direct replacements for competitive detectors. These are widely used in radiological surveys and monitoring equipment as well as industrial and laboratory applications. Please contact us should you wish to discuss specific requirements or references.
Our beta sensitive detectors have a wall thickness of 40-60 mg/cm2, (average 0.002"). They are used in many reactor safety monitoring systems and have proved to be very reliable even when used in semi-corrosive conditions at elevated temperatures.
Features
- This group of detectors covers a wide range of sensitivity to closely match our customer applications
- Well designed and proven construction ensures a long and reliable operating life
- Ideal for industrial control, area and site monitors, and reactor cooling system monitoring
- Cost effective, easy to use and very reliable with unmatched quality/cost ratio

| Thin Wall Detectors (for β, γ Applications) | |||
![]() |
![]() |
||
| Flying lead connections available for these models. Indicated by "-FL" suffix on order |
|||
| Characteristics | T2200 | T2202 | T2211 |
| Application | β, γ | β, γ | β, γ |
| Sensitivity*
137Cs cpm at 1 mR/h* |
5275 | 2900 | 1550 |
| Window Area Density (mg/cm2) | N/A | N/A | N/A |
| Window Effective Diameter (mm, in.) | N/A | N/A | N/A |
| Recommended Operating Voltage (HV+) | 900 | 900 | 900 |
| Plateau Length Volts min. | 850-1000 | 850-1000 | 850-1000 |
| Plateau Slope (%100 V max.) | 8 | 8 | 8 |
| Dead Time (µs max.) | 100 | 75 | 150 |
| Background (cpm)*** Shielding 2" Pb + 1/8" Al |
60 max. | 30 max. | 20 max. |
| Test Circuit | Figure 1 | Figure 1 | Figure 1 |
| Resistor Ra (MΩ) | 1.0 | 1.0 | 1.0 |
| Resistor R1 (MΩ) | 1.0 | 1.0 | 1.0 |
| Operating Temp. (°C) | -40 to +75** | -40 to +75** | -40 to +75 |
| Cathode Material | Cr/Fe | Cr/Fe | Cr/Fe |
| Cathode Wall | 40-60 mg/cm2 | 40-60 mg/cm2 | 40-60 mg/cm2 |
| Max. Length including Pins (mm, in.) | 276, 10.9 | 148, 5.83 | 110, 4.31 |
| Max. Overall Diameter (mm, in.) | 16.0, 0.63 | 16.0, 0.63 | 19.3, 0.75 |
| Window Recess (mm, in.) | N/A | N/A | N/A |
| * An exposure of 115.07 mR in air equates to 1.0 mGy. ** High temperature version available for 150 °C operation. *** At recommended operating voltage. |
|||
| Thick Wall Detectors (for γ Applications) | |||||
![]() |
![]() |
||||
| Flying lead connections available for these models. Indicated by "-FL" suffix on order |
|||||
| Characteristics | T2306 | T2311 | T2314 | T2316 | T2350 |
| Application | γ | γ | γ | γ | γ |
| Sensitivity*
137Cs cpm at 1 mR/h* |
950 | 1850 | 3050 | 3950 | 8150 |
| Window Area Density (mg/cm2) | N/A | N/A | N/A | N/A | N/A |
| Window Effective Diameter (mm, in.) | N/A | N/A | N/A | N/A | N/A |
| Recommended Operating Voltage (HV+) | 900 | 900 | 900 | 900 | 900 |
| Plateau Length Volts min. | 850-950 | 850-950 | 850-1000 | 850-1000 | 850-1000 |
| Plateau Slope (%100 V max.) | 8 | 8 | 6 | 6 | 10 |
| Dead Time (µs max.) | 100 | 100 | 100 | 100 | 120 |
| Background (cpm)*** Shielding 2" Pb + 1/8" Al |
12 max. | 30 max. | 47 max. | 60 max. | 100 max. |
| Test Circuit | Figure 1 | Figure 1 | Figure 1 | Figure 1 | Figure 1 |
| Resistor Ra (MΩ) | 3.3 | 3.3 | 3.3 | 3.3 | 3.3 |
| Resistor R1 (MΩ) | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
| Operating Temp. (°C) | -40 to +75 | -40 to +75 | -40 to +75 | -40 to +75 | -40 to +75 |
| Cathode Material | Cr/Fe | Cr/Fe | Cr/Fe | Cr/Fe | Cr/Fe |
| Cathode Wall | 0.25, 0.010 | 0.25, 0.010 | 0.25, 0.010 | 0.25, 0.010 | 0.25, 0.010 |
| Max. Length including Pins (mm, in.) | 86, 3.4 | 119, 4.7 | 165, 6.5 | 197, 7.75 | 351, 13.82 |
| Max. Overall Diameter (mm, in.) | 16.0, 0.63 | 16.0, 0.63 | 16.0, 0.63 | 16.0, 0.63 | 19.3, 0.76 |
| Window Recess (mm, in.) | N/A | N/A | N/A | N/A | N/A |
| * An exposure of 115.07 mR in air equates to 1.0 mGy. ** High temperature version available for 150 °C operation. *** At recommended operating voltage. |
|||||
| Detector Type | Applications |
| T2200 | Beta Monitor Industrial Safety System |
| T2202 | Beta Monitor Industrial Safety System |
| T2211 | Beta Monitor Industrial Safety System |
| T2306 | Gamma Monitor, Portable Monitoring System |
| T2311 | Gamma Monitor, Portable Monitoring System |
| T2314 | Gamma Monitor, Portable Monitoring System, Industrial Control |
| T2316 | Gamma Monitor, Portable Monitoring System, Industrial Control |
| T2350 | Area and site Monitoring |
| Related Industry Models | ||||
| CANBERRA | Centronics | LND | Saint Gobain | |
| Thin Wall Detectors | T2200 | ZP1860 | 719 | N107/3P |
| T2202 | ZP1850 | 721 | N106/3P | |
| T2211 | N/A | 725 | N112 | |
| Thick Wall Detectors | T2316 | N/A | 743 | N310/3P |
| T2350 | N/A | 78017 | N/A | |
GM Miniature Detectors
Description
The range of our Miniature GM Detectors offers a wide choice of sensitivity levels available to meet our customer requirements. From low level background environments to levels up to 1000 R/hr. gives our customer the opportunity to select the ideal detector for their application.
Robust construction and the ability to withstand excessive shock and vibration as required for military applications, makes these detectors an ideal choice for small hand held pocket dosimeters and small portable health physics monitors. Please contact us should you wish to discuss specific requirements or references.
Features
- Rugged construction designed to tolerate harsh operating conditions
- Halogen quenched to maximize operating life
- A wide range of sensitivities to suit customer needs
- Ideal for small monitoring equipment and personal health physics applications
- Low cost and very reliable over long periods of time

![]() |
Gamma Sensitive Miniature Detectors | ||||
![]() |
![]() |
![]() |
![]() |
||
| Anode pin connector and cathode strap are supplied. Stated wall thickness includes glass envelope and cathode wall where appropriate. To achieve maximum linear count rate, always solder Ra directly to the supplied anode pin connector, or to the anode flying lead. | |||||
| Characteristics | T2411M | T2416A | T2417A | T2420M | T2422 |
| Sensitivity*** 137Cs cpm at 1 mR/h* |
84 | 420 | 450 | 4.2 | 0.66 |
| Window Area Density (mg/cm2) | N/A | N/A | N/A | N/A | N/A |
| Window Effective Diameter (mm, in.) | N/A | N/A | N/A | N/A | N/A |
| Recommended Operating Voltage (HV+) | 575 | 575 | 575 | 500 | 460 |
| Plateau Length Volts min. | 500–650 | 500–650 | 500-650 | 450–550 | 450–550 |
| Plateau Slope (%100 V max.) | 15 | 8 | 8 | 35 | 40 max. |
| Dead Time (µs max.) | 15 | 45 | 45 | 20 | 10 |
| Background (cpm) Shielding 2" Pb + 1/8" Al |
2 max. | 12 max. | 5 max. | 6 typ. | 0.6 typ. |
| Test Circuit | Figure 2 | Figure 2 | Figure 2 | Figure 2 | Figure 2 |
| Resistor Ra (MΩ) | 2.2 | 4.7 | 4.7 | 4.7 | 4.7 |
| Operating Temp. (°C) | –40 to +75 | –40 to +75 | –40 to +75 | –51 to +71 | –20 to +60 |
| Cathode Material | Cr/Fe | Cr/Fe | Cr/Fe | Cr/Fe | Cr/Fe |
| Cathode Wall | 80–100 mg/cm2 |
64–80 mg/cm2 |
64–80 mg/cm2 |
360–400 mg/cm2 |
360–400 mg/cm2 |
| Max. Overall Length including Pins (mm, in.) | 37, 1.46 | 51, 2.0 | 46, 1.82 | 20, 0.8 | 20, 0.8 |
| Max. Overall Diameter (mm, in.) | 6.2, 0.244 | 10, 0.4 | 9.20, 0.36 | 7, 0.28 | 7, 0.28 |
| Window Recess (mm, in.) | N/A | N/A | N/A | N/A | N/A |
| * An exposure of 115.07 mR in air equates to 1.0 mGy. *** At recommended operating voltage. The T2422 detector is equivalent to the 3G10. |
|||||
![]() |
Gamma Sensitive Miniature Detectors | |||
![]() |
||||
| L – Max. Length without Leads
D – Max. Overall Diameter |
||||
| Characteristics | 3G70/ EM14752 3G70 |
4G60M/ EM14754 4G60M |
4G2500/ EM14749 4G2500 |
3G6500/ EM14748 3G6500 |
| Sensitivity*** 137Cs cpm at 1 mR/h* |
4.2 | 4.2 | 150 | 270 |
| Window Area Density (mg/cm2) | N/A | N/A | N/A | N/A |
| Window Effective Diameter (mm, in.) | N/A | N/A | N/A | N/A |
| Recommended Operating Voltage (HV+) | 460 | 500 | 550 | 460 |
| Plateau Length Volts min. | 420–500 | 450–550 | 500–600 | 420–500 |
| Plateau Slope (%100 V max.) | 30 | 30 | 25 | 25 |
| Dead Time (µs max.) | 25 | 25 | 35 | 50 |
| Background (cpm) Shielding 2" Pb + 1/8" Al |
0.6 max. | 0.6 max. | 6 max. | 10 max. |
| Test Circuit | Figure 2 | Figure 2 | Figure 2 | Figure 2 |
| Resistor Ra (MΩ) | 4.7 | 4.7 | 4.7 | 4.7 |
| Operating Temp. (°C) | –20 to +60 | –20 to +60 | –20 to +60 | –20 to +60 |
| Cathode Material | Cr/Fe | Cr/Fe | Cr/Fe | Cr/Fe |
| Cathode Wall | 360 mg/cm2 |
360 mg/cm2 |
260 mg/cm2 |
280 mg/cm2 |
| Max. Overall Length including Pins (mm, in.) | 34, 2.91 | 20, 2.36 | 34, 2.91 | 54, 3.7 |
| Max. Overall Diameter (mm, in.) | 7, 0.28 | 7, 0.28 | 7, 0.28 | 7, 0.28 |
| Window Recess (mm, in.) | N/A | N/A | N/A | N/A |
| * An exposure of 115.07 mR in air equates to 1.0 mGy. *** At recommended operating voltage. The T2422 detector is equivalent to the 3G10. |
||||
| Detector Type | Applications |
| T2411 | Dosimeters |
| T2411M | Military |
| T2416A | Dosimeters, Small Portable Monitors |
| T2417A | Dosimeters, Small Portable Monitors, Military |
| T2420M | Military |
| T2422 | Dosimeters, Small Portable Monitors |
| Related Industry Models | ||||
| CANBERRA | Centronics | LND | Saint Gobain | |
| Miniature Detectors | T2411 | ZP1310 | 714 | N116-1/C1310 |